Soundproofing Panels in Saudi Arabia — Product Catalog Overview

Al Yamamah Company offers a variety of products such as perforated wooden sound insulating panels and polyester foam sound absorbing panels which help absorb sound in Riyadh with high efficiency and provide a quiet and comfortable environment for everyone.
Soundproofing Panels in Saudi Arabia — Product Catalog Overview
Y

Yamamah Smart Team

Acoustic engineering & soundproofing specialists — Yamamah Smart

Riyadh residents, project owners, and contractors search daily for soundproofing panel catalog solutions grounded in verifiable standards. Eight major product families, one supplier, every test report on the public product pages. This guide explains the acoustic principle behind every decision, and the international reference numbers your project should meet.

Yamamah Smart acoustic installation
Yamamah Smart consultant reviewing acoustic panel samples with a Saudi client in a Riyadh showroom — soundproofing material consultation
Yamamah Smart product consultation in Riyadh — selecting the right acoustic materials

The Engineering Principle Behind Acoustic Treatment

Sound is a physical wave carrying energy. When it strikes a hard surface (concrete, glass, tile) it reflects back into the room, producing a long reverberation time RT60. Porous, fibrous materials such as PET Acoustic Panels convert that energy into a tiny amount of friction-heat inside their fibres — sound decays faster and the room feels comfortable.

Yamamah Smart acoustic materials showcase — wood wool, perforated wood, slat panels, fabric, foam pyramid, MLV roll, and absorption/insulation cross-sections
Full materials library: absorption, insulation, mass-loaded barriers, and finish surfaces

International Standards You Should Demand

The American standard ASTM C423 and the European ISO 354 define how NRC absorption is measured in a reverberation chamber. Yamamah Smart publishes the resulting reports openly on every product page — see for example PET Acoustic Panels. Never accept an NRC number from any supplier without an attached laboratory report.

Formula Mass Law for Sound Transmission
TL ≈ 20·log₁₀(m·f) − 47 (dB)

TL is transmission loss; m is mass per unit area (kg/m²); f is frequency (Hz). Doubling mass adds 6 dB to TL. A wall of 50 kg/m² at 500 Hz achieves TL ≈ 38 dB — but real assemblies (with decoupling and damping) often exceed this by 10–15 dB.

Referenced International Standards

ASTM E90
Laboratory transmission loss measurement
Reverberation-chamber test from which Sound Transmission Class (STC) is derived.
ASTM E413
Classification — Sound Transmission Class
Single-number rating computed from the measured 1/3-octave transmission loss curve.
ISO 717-1
Airborne sound insulation rating Rw
European equivalent of STC. Standard reporting for partitions and façades.
ASTM E492
Impact insulation measurement
Lab tapping-machine test for floor/ceiling assemblies — produces IIC (Impact Insulation Class).
EN 13501-1
Reaction-to-fire classification
Applies to MLV barriers and absorber components in residential and commercial walls.
BS 5852
Furniture & furnishing fire safety
Cigarette and match-flame ignition test — required for foam panel approvals.
Engineered acoustic meeting room in Riyadh with calibrated acoustic panels, ceiling baffles, and visualised sound wave reduction — STC and RT60 control
STC, RT60, and NRC targets are visualised as the wave field shrinks across the treated meeting room

Reference Target Values

Metric Target Source / Standard
Wall STC (residential) STC 50+ IBC 2015 §1207
Wall STC (executive) STC 55+ WELL Standard
Floor IIC (residential) IIC 55+ Design recommendation
Window STC (urban) STC 36+ (laminated double glazing) Manufacturer test
Door perimeter seal STC +6 to +10 over bare door ASTM E2074
MLV surface density 2–4 kg/m² Manufacturer spec
Yamamah Smart Saudi engineering team performing on-site acoustic measurement with sound level meter and material samples before fit-out
On-site dB measurement and material verification — the second step before any acoustic fit-out

Implementation Steps

1
Site assessment An engineer measures the existing acoustic environment — clap-test RT60, ambient dB(A), and surface inventory. Free service from Yamamah Smart.
2
Sabin calculation Using room volume and surface materials, we compute the absorbing area required to hit the target RT60. The result drives panel quantity.
3
Product selection Panel family is chosen by NRC target, fire rating, aesthetic, and budget. Verified test reports back every spec.
4
Layout & installation Panel layout is drawn against the architectural plan; installation uses approved mounting hardware (adhesive, Z-clip, or Button-Fix).
5
Post-install measurement After installation we re-measure RT60 and ambient dB(A) to confirm the design target was achieved. Report issued to the project owner.

How to Pick the Right Solution

Yamamah Smart engineers follow a documented process: measure the existing room, calculate the absorbing area needed via the Sabin formula, propose layered treatment (for example PET Acoustic Panels on walls + corner absorbers), then re-measure post-install to confirm the target was met.

Premium Riyadh restaurant with acoustic ceiling baffles, vertical wood slat dividers, and treated soft seating zones — Kingdom Tower skyline view
Hospitality fit-out example: ceiling baffles + slat dividers control conversation noise in a high-volume dining hall

Example Project Applications

Yamamah Smart has delivered installations across these categories in Saudi Arabia. Every project begins with a site survey, NRC calculation, and layered acoustic plan.

Corporate offices Open-plan workstations + glass-walled meeting rooms in Riyadh and Jeddah, treated with ceiling absorbers and wall fabric panels.
Hospitality & F&B Hotel lobbies, fine-dining restaurants, and busy cafés with hard floors and double-height ceilings — solved by suspended baffles + wall slats.
Education & worship Universities, classrooms, and mosques where speech intelligibility is the primary acoustic goal — controlled reverberation per ANSI S12.60.

Frequently Asked Questions

Will MLV alone soundproof my wall?
MLV is a key component but not a full solution. The proven assembly is gypsum + MLV + resilient channels + decoupled stud framing + mineral wool. Each layer addresses one of the four sound-management principles (mass, decoupling, damping, absorption).
How much can I expect STC to improve?
A standard 13 mm gypsum partition has STC ~35. Adding MLV + resilient channels + double-leaf gypsum typically reaches STC 50–55 — meeting the IBC 2015 §1207 residential requirements.
Does isolation work for low frequencies (bass)?
Low-frequency isolation requires mass — and mass works on a logarithmic scale. Doubling the mass adds ~6 dB transmission loss. For dedicated bass control (home cinema, music room) use MLV + thicker gypsum + mineral wool fill.
What about windows and doors — the weakest links?
Windows: upgrade to laminated acoustic double glazing (STC 36+). Doors: solid-core door + perimeter acoustic seal + automatic drop seal — together they add STC 8–12 over a hollow-core unsealed door.
How long does an acoustic project take in Saudi Arabia?
From site survey to commissioning, a typical commercial project takes 2–4 weeks. Residential treatments often complete in under a week. Yamamah Smart provides an indicative timeline at the survey stage.

Get a Free Acoustic Consultation

Our Yamamah Smart engineers assess your space and recommend the right panels with certified professional installation.

💬 WhatsApp: +966506600672 ✉ [email protected]

يبحث سكان الرياض والمستثمرون والمقاولون يومياً عن حلول كتالوج الألواح الصوتية عملية تعتمد على معايير قابلة للتحقّق. ثماني عائلات منتجات رئيسية، مورّد واحد، كل تقرير اختبار على صفحات المنتجات العامة. هذا الدليل يشرح المبدأ الصوتي وراء كل قرار، ويستعرض الأرقام المرجعية الدولية التي يجب أن يحقّقها مشروعك.

Yamamah Smart acoustic installation
مستشار ياممة سمارت يستعرض عيّنات الألواح الصوتية مع عميل سعودي في صالة عرض الرياض — استشارة مواد العزل الصوتي
استشارة منتجات ياممة سمارت في الرياض — اختيار المواد الصوتية المناسبة

المبدأ الهندسي وراء المعالجة الصوتية

الصوت موجة فيزيائية تحمل طاقة. عندما تصطدم بسطح صلب (خرسانة، زجاج، بلاط) ينعكس ويعود إلى الغرفة، مما يخلق ما يُعرف بـ زمن الرنين RT60 الطويل. المواد المسامية والليفية مثل ألواح PET الصوتية تحوّل هذه الطاقة إلى حرارة احتكاكية ضئيلة داخل أليافها، فيتلاشى الصوت أسرع وتشعر الغرفة بالراحة.

عرض مواد ياممة سمارت الصوتية — صوف خشبي، خشب مثقّب، ألواح بشرائح، قماش، فوم هرمي، لفّة MLV، ومقاطع الامتصاص/العزل
مكتبة المواد الكاملة: امتصاص، عزل، حواجز ثقيلة، وأسطح تشطيب

المعايير الدولية التي ينبغي أن تطلبها

المعيار الأمريكي ASTM C423 والأوروبي ISO 354 يحدّدان طريقة قياس معامل الامتصاص NRC في حجرة الصدى. التقارير الصادرة من هذه الاختبارات تنشرها اليمامة الذكية علناً على صفحات المنتجات — مثل صفحة ألواح PET الصوتية. لا تقبل من أي مورّد رقم NRC بدون تقرير مختبر مرفق.

المعادلة قانون الكتلة لانتقال الصوت
TL ≈ 20·log₁₀(m·f) − 47 (dB)

TL هو فقد الانتقال؛ m هي الكتلة لكل وحدة مساحة (كغ/م²)؛ f هو التردد (هرتز). مضاعفة الكتلة تضيف 6 ديسيبل إلى TL. جدار 50 كغ/م² عند 500 هرتز يحقّق TL ≈ 38 ديسيبل — لكن التجميعات الحقيقية (مع الفصل والتخميد) تتجاوزه عادةً بـ 10-15 ديسيبل.

المعايير الدولية المرجعية

ASTM E90
قياس فقد الانتقال في المختبر
اختبار حجرة الصدى الذي يُشتقّ منه فئة انتقال الصوت (STC).
ASTM E413
التصنيف — فئة انتقال الصوت
تصنيف واحد يُحسَب من منحنى فقد الانتقال بمقاييس الثلث-أوكتاف.
ISO 717-1
تصنيف العزل الصوتي الجوي Rw
المكافئ الأوروبي لـ STC. الإبلاغ القياسي للقواطع والواجهات.
ASTM E492
قياس عزل التأثير
اختبار آلة الطرق لتجميعات الأرضيات/الأسقف — يُنتج IIC (فئة عزل التأثير).
EN 13501-1
تصنيف رد الفعل للحريق
يطبّق على حواجز MLV ومكوّنات الممتصات في الجدران السكنية والتجارية.
BS 5852
سلامة الأثاث والمفروشات من الحريق
اختبار الإشعال بسيجارة ولهب — مطلوب لاعتماد ألواح الفوم.
غرفة اجتماعات مهندسة صوتياً في الرياض بألواح صوتية معايرة وبافلات سقفية مع تصوّر تقليل الموجات الصوتية — التحكم بـ STC و RT60
أهداف STC و RT60 و NRC تظهر مرئياً مع تقلّص حقل الموجات في غرفة الاجتماعات المعالَجة

الأرقام المرجعية

المقياس الهدف المصدر
Wall STC (residential) STC 50+ IBC 2015 §1207
Wall STC (executive) STC 55+ WELL Standard
Floor IIC (residential) IIC 55+ Design recommendation
Window STC (urban) STC 36+ (laminated double glazing) Manufacturer test
Door perimeter seal STC +6 to +10 over bare door ASTM E2074
MLV surface density 2–4 kg/m² Manufacturer spec
فريق ياممة سمارت الهندسي السعودي يجري قياساً صوتياً موقعياً بمقياس مستوى الصوت وعيّنات المواد قبل التركيب
قياس الديسيبل في الموقع والتحقق من المواد — الخطوة الثانية قبل أي تركيب صوتي

خطوات التنفيذ

1
تقييم الموقع مهندس يقيس البيئة الصوتية الحالية — RT60 باختبار التصفيق، ضجيج محيط dB(A)، وجرد الأسطح. خدمة مجانية من اليمامة الذكية.
2
حساب Sabin باستخدام حجم الغرفة والمواد السطحية، نحسب مساحة الامتصاص اللازمة لبلوغ RT60 المستهدف. النتيجة تحدّد عدد الألواح.
3
اختيار المنتج عائلة اللوح تُختار حسب NRC المستهدف وتصنيف الحريق والمظهر والميزانية. تقارير اختبار موثّقة تدعم كل مواصفة.
4
التوزيع والتركيب توزيع الألواح يُرسَم وفق المخطّط المعماري؛ التركيب يستخدم تثبيتاً معتمداً (لاصق، Z-clip، أو Button-Fix).
5
القياس بعد التركيب بعد التركيب نعيد قياس RT60 والضجيج المحيط للتأكّد من تحقّق الهدف. تقرير يُسلَّم لمالك المشروع.

كيف تختار حلّك المناسب

العملية التي يتّبعها مهندسو اليمامة الذكية بسيطة وموثّقة: قياس صوتي للغرفة الحالية، حساب مساحة الامتصاص اللازمة بمعادلة Sabin، اقتراح طبقات (مثلاً ألواح PET الصوتية على الجدار + ممتصات إضافية في الزوايا)، ثم القياس بعد التركيب للتأكّد من تحقّق الهدف.

مطعم فاخر في الرياض ببافلات صوتية سقفية وفواصل خشبية عمودية ومناطق جلوس معالَجة صوتياً — إطلالة على برج المملكة
مثال على تركيب الضيافة: البافلات السقفية + الفواصل الخشبية تتحكم بضوضاء المحادثات في قاعة طعام كبيرة

أمثلة على تطبيقات مماثلة

اليمامة الذكية نفّذت تركيبات مشابهة عبر هذه الفئات في المملكة. كل مشروع يبدأ بمسح موقع، حساب NRC، وخطة طبقات صوتية.

مكاتب الشركات محطات عمل مفتوحة + قاعات اجتماعات بجدران زجاجية في الرياض وجدة، تُعالَج بممتصات سقف وألواح قماشية للجدران.
الضيافة والأغذية والمشروبات ردهات الفنادق، مطاعم الطعام الفاخر، والمقاهي المزدحمة بأرضيات صلبة وأسقف مضاعفة — تُحَل ببفلات معلّقة + شرائح خشبية للجدران.
التعليم والعبادة الجامعات والصفوف والمساجد حيث وضوح الكلام هو الهدف الصوتي الرئيسي — رنين متحكَّم به وفق ANSI S12.60.

الأسئلة الشائعة

هل MLV وحده يعزل جداري صوتياً؟
MLV عنصر أساسي لكنه ليس حلاً كاملاً. التجميع المُثبَت هو جبس + MLV + قنوات مرنة + هيكل مفصول + صوف معدني. كل طبقة تعالج مبدأ من المبادئ الأربعة (الكتلة، الفصل، التخميد، الامتصاص).
كم يمكن لـ STC أن يتحسّن؟
قاطع جبس قياسي 13 مم له STC ~35. إضافة MLV + قنوات مرنة + جبس مزدوج تصل عادةً STC 50-55 — ملبّيةً متطلبات IBC 2015 §1207 السكنية.
هل العزل يعمل للترددات المنخفضة (الباس)؟
عزل الترددات المنخفضة يتطلّب كتلة — والكتلة تعمل على مقياس لوغاريتمي. مضاعفة الكتلة تضيف ~6 ديسيبل من فقد الانتقال. للتحكم المخصّص بالباس (سينما منزلية، غرفة موسيقى) استخدم MLV + جبس أسمك + تعبئة صوف معدني.
ماذا عن النوافذ والأبواب — أضعف الحلقات؟
النوافذ: ارتق إلى زجاج صوتي مزدوج مصفّح (STC 36+). الأبواب: باب صلب + ختم محيطي صوتي + ختم سفلي تلقائي — معاً يضيفون STC 8-12 فوق باب مجوّف غير مختوم.
كم تستغرق المعالجة الصوتية في السعودية؟
من مسح الموقع إلى التشغيل، يستغرق مشروع تجاري نموذجي 2-4 أسابيع. المعالجات السكنية تكتمل غالباً خلال أسبوع. اليمامة الذكية تقدّم جدولاً زمنياً إرشادياً في مرحلة المسح.

اطلب استشارة صوتية مجانية

فريق مهندسي اليمامة الذكية يقيّم مساحتك ويوصي بالألواح المناسبة مع تركيب احترافي معتمد.

💬 واتساب: 966506600672+ ✉ [email protected]

Share this article

Related articles

How to Soundproof a Bedroom — The Yamamah Smart KSA Toolkit
Acoustic Treatment

How to Soundproof a Bedroom — The Yamamah Smart KSA Toolkit

The bedroom is now an office, a podcast studio, and a sleep sanctuary all at once. This Yamamah Smart field toolkit covers the 5-piece bedroom acoustic stack — mass barrier, panels, door seal, window treatment, HVAC silencer — plus 3 strategies by budget and 5 KSA-specific use cases.